Customization: | Available |
---|---|
After-sales Service: | Online Service |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Laser dual station precision cutting, with good stability and high yield;
Having a high-precision visual positioning system and multi station collaborative work;
Fully automated loading, unloading, and cutting, with simple and convenient operation;
We have a self-developed system and a Chinese operating interface.
Name, Unit, Parameter, Remarks
True roundness (um)<1 before corrosion
Position degree (um)<1 before corrosion
Shape and dimensional tolerance (um)<2 before corrosion
Collapse edge (um)<2 before corrosion
Cone angle (°)>70 with a plane as the reference
Note:
This standard is calculated based on T ≤ 0.6 ± 0.01mm. For products exceeding this thickness and error, the technical requirements will be negotiated separately based on the actual achievable situation;
This standard is based on cutting circular holes, and the technical requirements for other non circular hole products are negotiated separately based on the actual achievable situation;
This efficiency is based on a thickness of 0.6mm and a diameter of φ Calculate based on a 0.05mm circle, and negotiate based on the actual achievable situation for other thicknesses or graphic products.
Laser China
Guanglu China
Cutting module China
Sports platform China
Mobile Module China
Control System China
Software China
Visual System China
Pneumatic components China
Electronic components China
Sensing System China
Name, Unit, Parameter, Remarks
Efficiency per S 1000 dual head
Yield% 97 Whole machine production yield (defect performance:
Scratches, automated debris, etc.)
Platform repeated positioning accuracy um ± 1
Platform positioning accuracy um ± 2.5
CPK ->1.33
Cutting range mm ≤ 205 * 205
Equipment weight T<4.8
Field service requirements
External dimensions (mm) 2390x2000x2000
Effective usage size (mm) 4390x4000x3000
Weight (Kg) 4500
Temperature: (ºC) 20-25 (7X24/h air conditioned)
Humidity: 20% to 70%
Power supply AC 220V/50Hz 32A single-phase
Power (KW) 5
Compressed air (bar) 6-10
Vacuum pressure (bar) -10 to -6
Working noise (dB) < 100
consume
Electric main